Lateral X-ray to control plate position Lateral X-ray to control plate position View the embedded image gallery online at: https://www.zbinetworkemea.com/fracture/index.php/treatment-example/vancouver-c-simple/item/132-plate-control#sigProIdb3b42055c6 Plate Control Before the screws are placed a lateral view to control the plate position is performed by use of the intensifier.